SOOW : | |
---|---|
Availability: | |
Quantity: | |
SOOW 6AWG 4C
6 Gauge SOOW Cable 20ft - 6/4 AWG 600V Electrical Wire for Welder Machine, Generator, Car Charger | Industrial Extension Cord
Length / Color | length color | Weight |
---|---|---|
64SOOW-FT | Per Foot / Black | 0.7 lb |
64SOOW-50 | 50ft / Black | 34.0 lb |
64SOOW-100 | 100ft / Black | 68.0 lb |
64SOOW-250 | 250ft / Black | 175.0 lb |
64SOOW-500 | 500ft / Black | 340.0 lb |
64SOOW-1000 | 1000ft / Black | 680.0 lb |
Product Description
Nominal OD: .89
36 Amps Per Conductor
Synthetic rubber insulation
Thermoset jacket
90°C
600 V
Specifications
CONDUCTOR: Bare, annealed copper per ASTM B-3, flexible, bunch stranded per UL 62, a separator may be applied over the conductor
INSULATION: Synthetic rubber per UL 62
COLOR CODE: Per ICEA Method 1, Table E-1 (up to 21/C) except 4/C which is black, white, green, red
ASSEMBLY: Insulated conductors are cabled with fillers as necessary to make round, a separator is applied over the assembly
OVERALL JACKET: Black, oil-resistant thermoset compound per UL 62
STANDARDS: Meets the UL 62 requirements for Type SOOW, also meets CSA requirements for Type SOOW, accepted by MSHA and printed with the manufacturer's P number
AMPACITY: Based on a 30°C ambient temperature per 2008 NEC Table 400.5(A), the values are derated (where applicable) according to 2008 NEC Article 400.5
TEMPERATURE: 90°C – VOLTAGE: 600 V
6 Gauge SOOW Cable 20ft - 6/4 AWG 600V Electrical Wire for Welder Machine, Generator, Car Charger | Industrial Extension Cord
Length / Color | length color | Weight |
---|---|---|
64SOOW-FT | Per Foot / Black | 0.7 lb |
64SOOW-50 | 50ft / Black | 34.0 lb |
64SOOW-100 | 100ft / Black | 68.0 lb |
64SOOW-250 | 250ft / Black | 175.0 lb |
64SOOW-500 | 500ft / Black | 340.0 lb |
64SOOW-1000 | 1000ft / Black | 680.0 lb |
Product Description
Nominal OD: .89
36 Amps Per Conductor
Synthetic rubber insulation
Thermoset jacket
90°C
600 V
Specifications
CONDUCTOR: Bare, annealed copper per ASTM B-3, flexible, bunch stranded per UL 62, a separator may be applied over the conductor
INSULATION: Synthetic rubber per UL 62
COLOR CODE: Per ICEA Method 1, Table E-1 (up to 21/C) except 4/C which is black, white, green, red
ASSEMBLY: Insulated conductors are cabled with fillers as necessary to make round, a separator is applied over the assembly
OVERALL JACKET: Black, oil-resistant thermoset compound per UL 62
STANDARDS: Meets the UL 62 requirements for Type SOOW, also meets CSA requirements for Type SOOW, accepted by MSHA and printed with the manufacturer's P number
AMPACITY: Based on a 30°C ambient temperature per 2008 NEC Table 400.5(A), the values are derated (where applicable) according to 2008 NEC Article 400.5
TEMPERATURE: 90°C – VOLTAGE: 600 V